MGE Galaxy 3500 20kVA 400V with 3 batt
Part# G35T20KH3B4S
EAN:0731304274995
MGE Galaxy 3500 with 3 Battery Modules Expandable to 4 - UPS - AC 380/400/415 V - 16 kW - 20000 VA - 3-phase - Ethernet 10/100, RS-232 - output connectors: 3
Native product specifications. The product description originates from Cnet. Foxway Distribution accepts no responsibility for error or misinformation in product descriptions from Cnet.
Product specifications
Product Description | MGE Galaxy 3500 with 3 Battery Modules Expandable to 4 - UPS - 16 kW - 20000 VA |
Manufacturer Warranty | 1-year warranty |
Dimensions (WxDxH) | 52.3 cm x 83.8 cm x 149 cm |
Weight | 535 kg |
Networking | Ethernet 10/100, RS-232 |
Device Type | UPS - external |
Battery | Lead Acid expandable |
Remote Management Protocol | SNMP 1, Telnet, SNMP 3, HTTP, HTTPS |
Input Voltage | AC 380/400/415 V |
Output Voltage | AC 400 V ± 5% |
Included Accessories | Bolt down brackets |
Run Time (Up To) | 11.7 min at full load |
Input Wiring | 3-phase |
Batteries Qty | 3 (installed) / 4 (supported) |
Power Capacity | 16 kW / 20000 VA |
Input Connectors | 1 x hardwire 5-wire (3PH + N + G) |
Output connectors | 1 x hardwire 4-wire (3PH + G) ¦ 1 x hardwire 5-wire (3PH + N + G) ¦ 1 x Terminal Block (Screw) |
General features
Device Type | UPS - external |
Portar
Interfaces | 1 x management (Ethernet) - RJ-45 ¦ 1 x management (RS-232) ¦ 1 x EPO (emergency power off) |
Expansion Slots | SmartSlot |
Warranty
Service & Support | Limited warranty - 1 year ¦ Installation - availability: 8 hours a day / Monday-Friday ¦ Configuration - availability: 8 hours a day / Monday-Friday |
Network
Remote Management Interface | Ethernet 10/100, RS-232 |
Remote Management Protocol | SNMP 1, Telnet, SNMP 3, HTTP, HTTPS |
Compliance
Included Accessories | Bolt down brackets |
Cables Included | Serial cable - external |
Features | Audible alarm, emergency power off, LCD display, built-in maintenance bypass, built-in static bypass |
Compliant Standards | ISO 9001, IEC 61000-3-2, IEC 61000-3-3, ISO 14001, EN 50091-2, IEC 62040-3, IEC 62040-1-1 |
HDD / SSD tolerance
Min Operating Temperature | 0 °C |
Max Operating Temperature | 40 °C |
Humidity Range Operating | 0 - 95% |
Sound Emission | 51.3 dBA |
Battery
Type | Expandable |
Quantity | 3 (installed) / 4 (supported) |
Technology | Lead Acid |
Run Time (Up To) | 11.7 min at full load |
Recharge Time | 5 hours |
Capacity
UPS Technology | On-line |
Input Voltage | AC 380/400/415 V |
Input Voltage Range | AC 304 - 477 V |
Input Voltage Range (Adjustable) | AC 340 - 460 V |
Frequency Provided | 47 - 53 Hz |
Input Wiring | 3-phase |
Frequency Required | 40 - 70 Hz |
Input Connectors | 1 x hardwire 5-wire (3PH + N + G) |
Power Output Connectors Details | 1 x hardwire 4-wire (3PH + G) ¦ 1 x hardwire 5-wire (3PH + N + G) ¦ 1 x Terminal Block (Screw) |
Output Voltage | AC 400 V ± 5% - 47 - 53 Hz |
Power Capacity | 16 kW / 20000 VA |
Output Waveform | Sinewave |
Surge Suppression | Yes |
Circuit Protection | Circuit breaker |
Physical dimensions
Width | 52.3 cm |
Depth | 83.8 cm |
Height | 149 cm |
Weight | 535 kg |
Shipping dimensions
Shipping Width | 65 cm |
Shipping Depth | 106 cm |
Shipping Height | 164 cm |
Shipping Weight | 565 kg |
Specifications
10-40kVA compact 3 phase UPS power protection with excellent efficiency and optimized footprint particularly adapted for demanding industrial environments.
- Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources. - Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used. - Parallel-redundant capable
Power the connected equipment with multiple UPSs to increase system redundancy. - Parallel-capacity capable
Increases total power capacity by using multiple UPSs simultaneously. - Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high efficiency. - Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault. - Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used. - Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling. - Excellent footprint
Small UPS footprint provides maximum usage of valuable electrical room floorspace.